Home / Products / Blue Green Algae Sensor /

Online Monitor Optical Chlorophyll Probe Sensor In Water SS316

Contact Now
Xi'an Desun Uniwill Electronic Technology Co., Ltd.
Province/State:Shaanxi
Country/Region:china
Contact Person:MrsWang
Contact Now

Online Monitor Optical Chlorophyll Probe Sensor In Water SS316

Ask Latest Price
Video Channel
Brand Name :Desun Uniwill
Model Number :DS430
Certification :CE
Place of Origin :China
MOQ :0-100PCS
Price :According to the specific quantity
Payment Terms :T/T, L/C, D/A, D/P
Delivery Time :7-15 working days
Packaging Details :carton packaging
Product name :Fiber Optic Chlorophyll Sensor
Principle :Fluorescence method
Measure range :0-400 ug/L
Resolution :0.1ug/l
Housing material :SS316
Power supply :5~12vdc,current <50mA (when not cleaned)
Output Signal :RS485, MODBUS protocol
IP grade :IP68
Deepest depth :Underwater 10 meters
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

RS485 Self-cleaning Chlorophyll Sensor Probe For Water Digital Chlorophyll Probe

Chlorophyll sensors typically utilize fluorescence or absorption techniques to quantify the chlorophyll content. Here are some key features of chlorophyll sensors:

Fluorometers:
Fluorometers are commonly used in chlorophyll sensors. They emit light at a specific wavelength and measure the fluorescence emitted by chlorophyll molecules when excited. The intensity of fluorescence is directly proportional to the concentration of chlorophyll in the sample.

Absorption Spectroscopy:
Chlorophyll sensors may also employ absorption spectroscopy to measure the concentration of chlorophyll. Absorption spectroscopy involves shining light of specific wavelengths onto the sample and measuring the amount of light absorbed by the chlorophyll molecules. The extent of absorption correlates with the chlorophyll concentration.

Multiple Wavelengths:
To accurately measure chlorophyll concentration, some sensors utilize multiple wavelengths. Different types of chlorophyll (such as chlorophyll a and chlorophyll b) absorb light at different wavelengths. By measuring absorption or fluorescence at multiple wavelengths, the sensor can di
fferentiate between various chlorophyll pigments and provide more detailed information about their concentrations.

Calibration:
Chlorophyll sensors require calibration to convert the measured fluorescence or absorption values into actual chlorophyll concentrations. Calibration involves using a known standard of chlorophyll and establishing a relationship between the sensor output and the chlorophyll concentration.

Water Correction:
In aquatic environments, the presence of water can interfere with the accuracy of chlorophyll measurements. As water absorbs and scatters light, it can affect the chlorophyll signal. Therefore, chlorophyll sensors often include algorithms or correction methods to account for the water's influence and provide accurate chlorophyll measurements.

Portable and Field-Friendly Design:
Chlorophyll sensors are often designed to be portable and suitable for field measurements. They may be handheld or mounted on autonomous platforms and equipped with built-in or external data storage capabilities for on-site measurements.

Integration with Water Quality Monitoring Systems:
Chlorophyll sensors can be integrated into larger water quality monitoring systems or networks. This allows for continuous, long-term monitoring of chlorophyll levels in different aquatic environments, providing valuable information for research, ecological assessments, and water management.

Description

The fiber-optic chlorophyll sensor adopts the principle of the fluorescence method. According to the spectral absorption characteristics of chlorophyll a, the water body is irradiated by a high-energy LED light source, and the chlorophyll a in the water body is excited to generate fluorescence of a specific wavelength, and the concentration of chlorophyll a in the water is measured. The sensor's fiber-optic structure provides excellent repeatability and stability and is less susceptible to ambient light. With automatic cleaning, the brush eliminates air bubbles, reduces the impact of contamination on the measurement, makes the maintenance cycle longer, and maintains excellent stability for long-term online use.

Online Monitor Optical Chlorophyll Probe Sensor In Water SS316

Feature
* Digital sensor, RS-485 output, support MODBUS.
* Automatic cleaning brush to prevent contamination and eliminate air bubbles
* Direct measurement is easier than traditional analysis methods
* Continuous online monitoring and real-time control of water quality
Technical parameter
Item
Specifications
Product name
Fiber optic chlorophyll sensor
Self-cleaning chlorophyll sensor
Model
DS430
DS431
Principle
Fluorescence method
Range
0~400 ug/L or 0 ~100 RFU
Resolution
0.1μg/L or 0.1% RFU
Linearity
R2>0.99
Temperature range
0~ 50°C
Protection level
Ip68
Sensor interface
Support RS-485, MODBUS protocol
Installation
Input type, Circulation type
Power information
DC 5~12V, current <50mA
size
Φ22*120mm
Probe cable length
10 meters (default), can be customized
Housing material
POM
SS316

Inquiry Cart 0