Xi'an Desun Uniwill Electronic Technology Co., Ltd.

Our Vision Aspire to be a leader in water quality monitoring - our pursuit is to be respected by customers, employees, partners and other companies in the industry. Core Values Rigorous, Efficient,

Manufacturer from China
Site Member
4 Years
Home / Products / Water Dissolved Oxygen Sensor /

0 - 20ppm Dissolved Oxygen Electrode Probe Nitrogen Residual Chlorine Sensor

Contact Now
Xi'an Desun Uniwill Electronic Technology Co., Ltd.
Province/State:Shaanxi
Country/Region:china
Contact Person:MrsWang
Contact Now

0 - 20ppm Dissolved Oxygen Electrode Probe Nitrogen Residual Chlorine Sensor

Ask Latest Price
Video Channel
Brand Name :Desun Uniwill
Model Number :DS-380
Certification :CE
Place of Origin :China
MOQ :0~100 pcs
Price :$280.00 - $400.00/ Piece
Payment Terms :L/C, D/A, D/P, T/T
Supply Ability :0~1000 pcs
Delivery Time :7~ 15 working days
Packaging Details :Carton packaging
Measuring range :0~20mg/L or 0-200% saturation
Response time :3 seconds
Accuracy :1%
Protection level :IP68
Installation :Submersible
Temperature sensor :NTC
Temperature range :0~50°C
Temperature accuracy :±0.2°C
Output :RS-485, MODBUS protocol
Probe cable length :Default 5 m
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

0~20ppm Dissolved Oxygen Sensor DO Electrode Probe Nitrogen Dissolved Oxygen Residual Chlorine Sensor

Introduction

The optical fluorescence dissolved oxygen sensor is based on the physics principle of quenching the specific light fluorescence of a particular substance.The blue light from the light emitting diode (LED) illuminates the fluorescent material on the inner surface of the fluorescent cap, which is excited to emit red light by detecting the phase difference between the red and blue light and the internal calibration values.

0 - 20ppm Dissolved Oxygen Electrode Probe Nitrogen Residual Chlorine Sensor


The ratio is calculated to calculate the concentration of oxygen molecules and the final value is automatically compensated for by temperature and pressure.

Technical Parameters

Item Parameters
Model DS380
Principle Fluorescence analysis method
Measuring range 0~20mg/L or 0-200% saturation
Response time 3 sec
Accuracy 1%
Protection level IP68
Installation Submersible
Temperature sensor NTC
Temperature range 0~50°C
Temperature accuracy ±0.2°C
Output Support RS-485, MODBUS protocol
Power supply DC 6~12V, current <50mA
Size Φ26*155 mm
Probe cable length Default 5 m, customized 10m, 15 m and 30 m cable
Fluorescent cap life 1 year
Maximum working pressure 6bar
product material POM/SS316/Titanium alloy
Calibration method One or Two-point calibration
Power consumption < 0.5 W

FAQ

Q: Can you offer OEM services?
A: Yes,we support OEM and ODM products according to your requirements.

Q: What are your terms of payment and delivery time?
A: We could accept T/T, Paypal, Western Union, Credit Assurance. Generally, we will arrange the shipment within 7 days after received payment.

Q: How about warranty?
A: 12 months warranty

0 - 20ppm Dissolved Oxygen Electrode Probe Nitrogen Residual Chlorine Sensor

Inquiry Cart 0