| Item | Parameters | 
| Output signal | Support RS-485, MODBUS protocol | 
| Range | TOC 1.5 to 410mg/l equiv KHP, COD 2.5 to 1000 mg/l equiv. KHP | 
| Accuracy | 0.01mg/L COD | 
| Temperature range | +5 ~ 45°C | 
| IP Grade | IP68 | 
| Maximum pressure | 1 bar | 
| Calibration | 1 or 2 point COD calibration | 
| Power Supply | DC 12V +/-5%, current <50mA (when there is no cleaning brush) | 
| Sensor Size | 54*325.5 mm | 
| Cable length | 5m (default) | 
| Housing Material | POM/ SS316L | 
Common problem
| Error | Possible causes | Solutions | 
| Unstable reading | Connection failure | Reconnect the controller and cables | 
| Cable failure | Please contact us | |
| Measured values are too high, too low, or the values remain unstable | The sensor measurement window is blocked | Cleaning surface | 